Table of Contents(Page SSR-33)
SSR SYSTEMS PRICING

ITEM

DESCRIPTION PRICE PER EACH
RIDGE FLASHING FLOATING

 

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-200 3 1/2" 10'-2" 15 1/2" 10.63# 1/4-2 1/2:12 23.90 28.12 36.00 40.33
FL-202 4½" 10'-2" 17 1/2" 12.00# 2 9/6-4:12 25.86 30.70 39.56 44.35
NOTE: For use without ventilator - 18’ Peak purlin spacing.        
FL-213  6 1/2" 10'-2" 21 1/2" 14.74# 1/4-2 1/2:12 29.21 35.08 45.99 52.02
FL-214 7½" 10'-2" 23 1/2" 16.17# 2 9/16-4:12 31.27 37.75 49.62 56.09
NOTE: For use without ventilator 24" Peak purlin spacing.        
FL-205 10 1/4" 10'-2" 29" 19.88# 1/4-2 1/2:12 37.14 45.38 60.00 67.21
FL-207 11" 10'-2" 30½" 20.91# 2 9/16-4:12 38.63 47.28 62.68 70.25
NOTE: For use with 9" ventilator only - 32" Peak purlin spacing.        
FL-200 3½" 10'-2" 15 1/2" 10.63# 1/2-3 3/4:12 23.90 28.12 36.00 40.33
FL-202 4½" 10'-2" 17 1/2" 12.00# 3 13/16-6:12 25.86 30.70 39.56 44.35
NOTE: For use without vent material-18" peak purlin spacing.        
FL-213 6 1/2" 10'-2" 21 1/2" 14.74# 1/2-3 ¾:12 29.21 35.08 45.99 52.02
FL-214 7½" 10'-2" 23 1/2" 16.17# 3 13/16-6:12

31.27

37.75

49.62

56.09

NOTE: For use without ventilator - 24" Peak purlin spacing.        
RIDGE FLASHING
FOR PLASTIC VENT

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-300 4 1/2" 10'-2" 19 1/2" 13.37# 1/2-3 ¾:12 29.72 35.13 44.96 50.37
FL-302 5 1/2" 10'-2" 21 1/2" 14.74# 3 13/16-6:12 31.68 37.70 48.52 54.39

NOTE: For use with plastic vent material—18" Peak Purlin Spacing.

       
FL-303 7 ½" 10'-2" 25 ½" 18.37# 1/2-3 ¾:12

35.02

42.08

54.96

62.06

FL304 8 ½" 10'-2" 27 1/2" 19.74# 3 13/16-6:12 37.03 44.76 58.56 66.08
NOTE: For use with plastic vent material—24" Peak Purlin Spacing.        
RIDGE/HIP FLASHING

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-209 6" 10'-2" 13" 8.91# 1/2-3 3/4:12 17.62 21.27 27.81 31.16
FL-211 7" 10'-2" 15" 10.28# 3 13/16-6:12 19.63 23.85 31.37 35.18
NOTE: For use without vent material-18" Peak Purlin Spacing.        
FL-212 11 ½" 10'-2" 24" 15.88# 1/2-3 3/4:12

32.24

35.59

48.11 54.54

NOTE: For use without vent material—24" Peak Purlin Spacing.

       
RIDGE FLASHING
FOR METAL VENT

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-540 5 1/2" 10'-2" 22¼" 14.92# ½-3:12 32.24 38.37 49.60 55.57
FL-541 6" 10'-2" 23¼" 15.64# 3 1/8-5:12 33.12 39.56 51.30 57.48
NOTE: For use with metal vent—18" Peak Purlin Spacing.        
FL-543 8½" 10'-2" 28 ¼" 18.94# ½-3:12 37.60 45.38 59.64 67.21
FL-544 9" 10'-2" 29 ¼" 19.67# 3 1/8-5:12

38.48

46.56

61.34

69.12
NOTE: For use with metal vent—24" Peak Purlin Spacing.        
RIDGE FLASHING

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-545 8 7/8" 10'-2" 21 ½" 14.74# ½-3:12 27.04 33.12 43.99 49.29
FL-546 9 1/2" 10'-2" 22 3/4" 15.37# 3 1/8-5:12 28.12 34.61 46.10 51.66
NOTE: For use with metal vent—18" Peak Purlin Spacing.        
FL-547 11 ½" 10'-2" 27½" 18.85# 1/2-3:12 32.40 40.17 54.08 60.83
FL-548 12 1/2" 10'-2" 28 ¾" 19.42# 3 1/8-5:12

33.48

41.67

56.19 63.20
NOTE: For use with metal vent—24" Peak Purlin Spacing.        

Signature is a registered trademark of Metal Building Components, L.P. Galvalume Plus is a registered and protected trademark of BIEC International, Inc.
Consult the ASBC TECHNICAL MANUAL for proper product application, design details, and other product information.

Back   Next